Modular Units’ Tests for Treatment of Unbalanced Water of Outdoor Storage Pools of Liquid Radioactive Waste
https://doi.org/10.18412/1816-0395-2017-4-8-12
Abstract
There was conducted tests of membrane plants for water treatment of Techa’s water reservoirs / Scheme of reservoir’s low level solutions’ treatment is based on a combination of ultrafiltration methods and two-stage reverse osmosis. During tests was processed 2500 m3 of liquid radioactive waste and obtained treated water with solid contents from 0.1 to 2.0 mg/l of the total volume and activity of beta-emitting nuclides from 0.04 to 1.2 Bq/l.
About the Authors
P.A. BobrovRussian Federation
Research Supervisor
O.M. Slyuntchev
Russian Federation
Cand. Sci. (Eng.), Team Manager
References
1. Баранов С.В., Баторшин Г.Ш., Мокров Ю.Г. и др. Теченский каскад водоёмов ФГУП "ПО "Маяк": Текущее состояние и перспективы. Вопросы радиационной безопасности. 2011. № 1. С.5-14.
2. Шаталов В.В., Соловьев В.Г., Щеглов А.Ю. и др. Испытания мембранно-сорбционной очистки теченского каскада водоемов. Атомная энергия. 2008. Т. 105. С.278-284.
3. Слюнчев О.М., Иванов И.А., Мокров Ю.Г. Разработка технологий очистки воды Теченского каскада водоемов. Российский химический журнал. 2010. № 3. Т. LIV. С.144-152.
4. Слюнчев О.М., Козлов П.В., Ровный С.И. и др. Обоснование перспективных технических решений по очистке воды Теченского каскада водоемов. Вопросы радиационной безопасности. 2007. № 2. С.14 – 26.
5. Рябчиков Б.Е. Очистка жидких радиоактивных отходов. М.: ДеЛи принт, 2008. 516 с.
Review
For citations:
Bobrov P., Slyuntchev O. Modular Units’ Tests for Treatment of Unbalanced Water of Outdoor Storage Pools of Liquid Radioactive Waste. Ecology and Industry of Russia. 2017;21(4):8-12. (In Russ.) https://doi.org/10.18412/1816-0395-2017-4-8-12